Mepco (Dunham Bush) steam traps and repair parts for radiator traps: Models 1E-SS, 2E-SS and 3C-SS. All the new Mepco radiator steam traps come with stainless steel removable seats. The repair parts fix both the -SS style traps and the old style 1E, 2E and 3C models. Select 90 degree angle pattern, horizontal, straight-through or vertical piping pattern styles. Pipe sizes from 1/2 inch to 1 inch. Steam operating pressures up to 25 psig. Dunham-Bush (Mepco) steam traps. Replacement thermostats, trap union nipples and covers on the shelf ready for shipping. Download the State Supply Steam Trap Repair & Maintenance catalog, jam-packed with schematic drawings, capacity tables and repair part ordering tables. All parts and steam traps ready for same-day shipping from State Supply.

per page
Set Descending Direction

List Grid |

Items 1-10 of 11

Page:
  1. 1
  2. 2
  1.  Mepco (D&B) Radiator Trap, Model 1ESS-AP

    Mepco (D&B) Radiator Trap, Model 1ESS-AP

    SKU: DM1056

    Mepco angle pattern thermostatic trap model 1ESS AP 1/2"pipe with removable stainless steel seat. 25lb maximum operating pressure, capacity 1,270 square feet EDR. Capacities for low pressure heating systems using thermostatic traps are rated in EDR (Equivalent Direct Radiation). One square foot EDR is equivalent to an output of 240 BTU's per hour or 0.25lbs of condensate. Learn More
    $70.00
  2.  Mepco (D&B) Radiator Trap, Model 1ESS-LH

    Mepco (D&B) Radiator Trap, Model 1ESS-LH

    SKU: DM1059

    Mepco left hand pattern thermostatic trap model 1ESS LH 1/2"pipe 25lb maximum operating pressure, capacity 1,270 square feet EDR. Capacities for low pressure heating systems using thermostatic traps are rated in EDR (Equivalent Direct Radiation). One square foot EDR is equivalent to an output of 240 BTU's per hour or 0.25lbs of condensate. Learn More
    $115.32
  3.  Mepco (D&B) Radiator Trap, Model 1ESS-RH

    Mepco (D&B) Radiator Trap, Model 1ESS-RH

    SKU: DM1058

    Mepco right hand pattern thermostatic trap model 1ESS RH 1/2"pipe 25lb maximum operating pressure, capacity 1,270 square feet EDR. Capacities for low pressure heating systems using thermostatic traps are rated in EDR (Equivalent Direct Radiation). One square foot EDR is equivalent to an output of 240 BTU's per hour or 0.25lbs of condensate. Learn More
    $115.32
  4.  Mepco (D&B) Radiator Trap, Model 1ESS-SW

    Mepco (D&B) Radiator Trap, Model 1ESS-SW

    SKU: DM1057

    Mepco straight pattern thermostatic trap model 1ESS SW 1/2"pipe 25lb maximum operating pressure, capacity 1,270 square feet EDR. Capacities for low pressure heating systems using thermostatic traps are rated in EDR (Equivalent Direct Radiation). One square foot EDR is equivalent to an output of 240 BTU's per hour or 0.25lbs of condensate. Learn More
    $119.97
  5.  Mepco (D&B) Radiator Trap, Model 1ESS-VS

    Mepco (D&B) Radiator Trap, Model 1ESS-VS

    SKU: DM1064

    Mepco vertical pattern thermostatic trap model 1EVS 1/2"pipe 25lb maximum operating pressure, capacity 1,270 square feet EDR. Capacities for low pressure heating systems using thermostatic traps are rated in EDR (Equivalent Direct Radiation). One square foot EDR is equivalent to an output of 240 BTU's per hour or 0.25lbs of condensate. Learn More
    $122.76
  6.  Mepco (D&B) Radiator Trap, Model 1R - Replaces old -02H

    Mepco (D&B) Radiator Trap, Model 1R - Replaces old -02H

    SKU: DM1070

    Mepco angle pattern thermostatic trap model 1R 1/2"pipe 25lb maximum operating pressure, capacity 1,270 square feet EDR. Exact piping-in configuration as the old Warren-Webster 02H series of 1/2" angle pattern radiator traps. Learn More
    $126.48
  7.  Mepco (D&B) Radiator Trap, Model 2ESS-AP

    Mepco (D&B) Radiator Trap, Model 2ESS-AP

    SKU: DM1076

    Mepco angle pattern thermostatic trap model 2ESS 3/4"pipe 25lb maximum operating pressure, capacity 2,450 square feet EDR. Capacities for low pressure heating systems using thermostatic traps are rated in EDR (Equivalent Direct Radiation). One square foot EDR is equivalent to an output of 240 BTU's per hour or 0.25lbs of condensate. Learn More
    $129.27
  8.  Mepco (D&B) Radiator Trap, Model 2ESS-SW

    Mepco (D&B) Radiator Trap, Model 2ESS-SW

    SKU: DM1081

    Mepco straight pattern thermostatic trap model 2ESS 3/4"pipe 25lb maximum operating pressure, capacity 2,450 square feet EDR. Capacities for low pressure heating systems using thermostatic traps are rated in EDR (Equivalent Direct Radiation). One square foot EDR is equivalent to an output of 240 BTU's per hour or 0.25lbs of condensate. Learn More
    $164.61
  9.  Mepco (D&B) Radiator Trap, Model 3ESS-AP

    Mepco (D&B) Radiator Trap, Model 3ESS-AP

    SKU: DM1084

    Mepco angle pattern thermostatic trap model 3CSS 1"pipe 25lb maximum operating pressure, capacity 3,100 square feet EDR. Capacities for low pressure heating systems using thermostatic traps are rated in EDR (Equivalent Direct Radiation). One square foot EDR is equivalent to an output of 240 BTU's per hour or 0.25lbs of condensate. Learn More
    $170.19
  10.  Mepco (D&B) Thermostatic Trap, Model TH1A-AP

    Mepco (D&B) Thermostatic Trap, Model TH1A-AP

    SKU: DM1072

    Mepco angle pattern industrial thermostatic trap model TH1A 1/2"pipe 100lb maximum operating pressure, capacity 2,600lbs per hour. Learn More