Danfoss 013G0290 - Packing Gland for RA-2000 Valves
Danfoss packing gland for all RA-2000 series valves.
(877) 775-7705 ~ We're currently open! Hours
Not sure if you have a State Supply account? Try to reset your password.
You don't need an account to purchase from us, but without an account you will miss out on a few important features:
Danfoss packing gland for all RA-2000 series valves.
Danfoss packing gland for older RAV series valves.
Danfoss 12-24V DC and 100-240V AC (50/60Hz) switching electronic unit for BD35F direct current compressors. This unit is UL/VDE approved.
Danfoss 24V expansion valve control.
Danfoss 3/4" electrically-operated expansion valve without coil for R22/R407C, R134A, and R404A/R507 refrigerants.
Danfoss 3/8" x 1/2" thermostatic expansion valve with 5' capillary tube for R134A refrigerant. This valve has an N range of -40°F to 50°F.
Danfoss 3/8" x 1/2" thermostatic expansion valve with 5' capillary tube and MOP for R404A and R507 refrigerant. This valve has a NM range of -40°F to 25°F.
Danfoss 3/8" x 1/2" thermostatic expansion valve with 5' capillary tube and MOP for R404A and R507 refrigerant. This valve has a B range of -75°F to -15°F.
Danfoss 3/8" x 1/2" thermostatic expansion valve with 5' capillary tube and MOP for R404A and R507 refrigerant. This valve has a B range of -75°F to -15°F.
Danfoss 1-1/8" x 1-3/8" thermostatic expansion valve with 9.84' capillary tube for R134A refrigerant. This valve has an N range of -40°F to 50°F.
Danfoss 3/4" electrically-operated expansion valve without coil for R22/R407C, R134A, and R404A/R507 refrigerants.
Danfoss thermostatic element and valve body with bulb strap for R22 refrigerant. This valve features a 5' capillary tube, 3/8" inlet x 1/2" outlet, -40°F to 50°F temperature range, external pressure equalization, and is without MOP (maximum operating pressure).
Danfoss thermostatic element and valve body with bulb strap for R134A refrigerant. This valve features a 5' capillary tube, 3/8" inlet x 1/2" outlet, -40°F to 50°F temperature range, internal pressure equalization, and is without MOP (maximum operating pressure).
Danfoss thermostatic element and valve body with bulb strap for R134A refrigerant. This valve features a 5' capillary tube, 3/8" inlet x 1/2" outlet, -40°F to 50°F temperature range, external pressure equalization, and is without MOP (maximum operating pressure).
Danfoss thermostatic element and valve body with bulb strap for R404A and R507 refrigerant. This valve features a 5' capillary tube, 3/8" inlet x 1/2" outlet, -40°F to 50°F temperature range, internal pressure equalization, and is without MOP (maximum operating pressure).
Danfoss thermostatic element and valve body with bulb strap for R404A and R507 refrigerant. This valve features a 5' capillary tube, 3/8" inlet x 1/2" outlet, -40°F to 50°F temperature range, external pressure equalization, and is without MOP (maximum operating pressure).
Danfoss thermostatic element, less orifice and filter, with bulb strap for R134A refrigerant. This valve features a 1.5m capillary tube, 3/8" inlet x 1/2" outlet, -40°F to 10°F temperature range, internal pressure equalization, and is without MOP (maximum operating pressure).
Danfoss thermostatic element, less orifice and filter, with bulb strap for R134A refrigerant. This valve features a 1.5m capillary tube, 3/8" inlet x 1/2" outlet, -40°F to 10°F temperature range, external pressure equalization (1/4"), and is without MOP (maximum operating pressure).
Danfoss thermostatic element, less orifice and filter, with bulb strap for R22 refrigerant. This valve features a 1.5m capillary tube, 3/8" inlet x 1/2" outlet, -40°F to 10°F temperature range, internal pressure equalization, and is without MOP (maximum operating pressure).
Danfoss thermostatic element, less orifice and filter, with bulb strap for R404A and R507 refrigerant. This valve features a 1.5m capillary tube, 1/4" inlet x 1/2" outlet, -40°F to 10°F temperature range, internal pressure equalization, and is without MOP (maximum operating pressure).
Danfoss thermostatic element, less orifice and filter, with bulb strap for R404A and R507 refrigerant. This valve features a 1.5m capillary tube, 3/8" inlet x 1/2" outlet, -40°F to 10°F temperature range, internal pressure equalization, and is without MOP (maximum operating pressure).
Danfoss thermostatic element, less orifice and filter, with bulb strap for R404A and R507 refrigerant. This valve features a 1.5m capillary tube, 3/8" inlet x 1/2" outlet, -40°F to 10°F temperature range, external pressure equalization (1/4"), and is without MOP (maximum operating pressure).
Danfoss thermostatic expansion valve with adjustable setting for R22 refrigerant. This valve features a no. 4 orifice, 3/8" inlet x 1/2" outlet x 1/4" equalizer, 14-59°F temperature range, 4.5 TR and 15.8 kW capacity, and 20" capillary tube.
Danfoss thermostatic expansion valve with adjustable setting for R22 refrigerant. This valve features a no. 5 orifice, 3/8" inlet x 1/2" outlet x 1/4" equalizer, 14-59°F temperature range, 5.3 TR and 18.5 kW capacity, and 20" capillary tube.
Danfoss thermostatic expansion valve with adjustable setting for R22 refrigerant. This valve features a no. 6 orifice, 3/8" inlet x 1/2" outlet x 1/4" equalizer, 14-59°F temperature range, 5.6 TR and 19.6 kW capacity, and 20" capillary tube.
Danfoss thermostatic expansion valve with adjustable setting for R22 refrigerant. This valve features a no. 7 orifice, 3/8" inlet x 1/2" outlet x 1/4" equalizer, 14-59°F temperature range, 6.7 TR and 23.6 kW capacity, and 20" capillary tube.
Danfoss thermostatic expansion valve with adjustable setting for R410A refrigerant. This valve features a no. 3 orifice, 3/8" inlet x 1/2" outlet x 1/4" equalizer, 14-59°F temperature range, 3 TR and 10.5 kW capacity, and 20" capillary tube.
Danfoss thermostatic expansion valve with adjustable setting for R410A refrigerant. This valve features a no. 5 orifice, 3/8" inlet x 1/2" outlet x 1/4" equalizer, 14-59°F temperature range, 5 TR and 17.5 kW capacity, and 20" capillary tube.
Danfoss blue magnet tester for valves.
Danfoss general purpose 110v coil with NEMA 2 junction box and 7" wire for solenoid valves.
Danfoss 110-120v coil with NEMA 4 conduit boss and 18" wire for solenoid valves.
Danfoss general purpose 230v coil with NEMA 2 junction box and 7" wire for solenoid valves.
Danfoss 120v coil with DIN plugs and protection cap for solenoid valves.
Danfoss 208-240v, 14W coil with DIN connectors for solenoid valves.
Danfoss solid core, made of 80% molecular sieve and 20% AI3O3 material, with gasket for DCR 0485 to 19217 filter driers.
Danfoss Eliminator liquid line filter drier with 5/8" flare connection.
Danfoss Eliminator liquid line filter drier with 1/4" flare connection and wire mesh in the outlet.
Danfoss seal kit for EVR 4, EVR 6, EVR 8, and EVR 6 NO solenoid valves. This kit contains an o-ring and gaskets.
Danfoss service kit, which contains a diaphragm, o-ring for armature tube, four (4) T20 screws, four (4) T15 screws, armature assembly, rubber gasket, o-ring for steel cover, square cover, square gasket for steel cover, and support ring for EVR 6 solenoid valves.
Danfoss spare parts kit.
Danfoss 4-wire, 2-meter long M12 female connector cable with CPE jacket with a -40°F to 80°F temperature range for type KVS electronic suction modulating valves.
Danfoss 208-240v RC coil.
Danfoss 24VDC, 15W coil with DIN connection for solenoid valves.
Danfoss #03 orifice assembly with filter for T 2 thermostatic expansion valves.
Danfoss #01 orifice assembly with filter for T 2 thermostatic expansion valves.
Danfoss #02 orifice assembly with filter for T 2 thermostatic expansion valves.
Danfoss #06 orifice assembly with filter for TUA and TUAE thermostatic expansion valves.
Danfoss stainless steel thermostatic expansion valve for R134A refrigerant. This valve features a 2-1/2' capillary tube, 3/8" inlet x 1/2" outlet, and -40°F to 50°F temperature range.
Danfoss AKS 12 sensor with 1.5m cable for temperatures between -40°C and 100°C.
Page 1 of 8