Warrick 16B1B0 - Level Control
Warrick general purpose, direct-acting, 120v, 1/8" standoff panel mount level control with 10,000 ohm sensitivity.
(877) 775-7705 ~ We're currently open! Hours
Not sure if you have a State Supply account? Try to reset your password.
You don't need an account to purchase from us, but without an account you will miss out on a few important features:
Warrick general purpose, direct-acting, 120v, 1/8" standoff panel mount level control with 10,000 ohm sensitivity.
Warrick DPDT load contact level control featuring 0-1M ohm factory set sensitivity, two normally open and two normally closed contacts, a 5 amp resistive 1/10 HP contact rating, 10k direct mode of operation, 120v, 11 pin octal socket.
Warrick DPDT load contact level control featuring 0-1M ohm factory set sensitivity, two normally open and two normally closed contacts, a 5 amp resistive 1/10 HP contact rating, 10k direct mode of operation, 120v, DIN mount socket.
Warrick DPDT load contact level control featuring 0-1M ohm factory set sensitivity, two normally open and two normally closed contacts, a 5 amp resistive 1/10 HP contact rating, 26k direct mode of operation, 120v, 11 pin octal socket.
Warrick dual function, direct-action, 120v, retrofit level control board with 26,000 ohm sensitivity.
Warrick general purpose, direct acting, 120v, 1/16" standoff panel level control with a 2-second delay and 26,000 ohm sensitivity.
Warrick general purpose, 120v, direct acting, 8 pin octal socket level control relay with 10,000 ohm sensitivity.
Warrick general purpose, 120v, direct acting, 8 pin bin socket level control relay with a NEMA 1 enclosure with 10,000 ohm sensitivity.
Warrick stainless steel two-piece 3/8"-18 NPT threaded coupling rated for 400 psig at 406°F.
Warrick stainless steel two-piece 5/8"-18 UNF threaded coupling rated for 400 psig at 406°F.
Warrick stainless steel two-piece 5/8"-24 UNEF threaded coupling rated for 250 psig at 406°F.
Warrick 6" cast iron short external mount side chamber with two stainless steel probes, rated for 250 psig at 406°F.
Warrick 2' stainless steel 1/4" threaded rod style probe.
Warrick 3' stainless steel 1/4" threaded rod style probe.
Warrick 4' stainless steel 1/4" threaded rod style probe.
Warrick stainless steel wire suspended probe with a polyethylene body.
Warrick copper washer for Series 3B fittings.
Warrick dual function, direct acting, screw mount, 120v level control with 26,000 ohm sensitivity, one normally-open and one normally-closed contact.
Warrick dual function, inverse acting, 1/16" standoff panel mount, 120v level control with 10,000 ohm sensitivity, power outage, reset function, 4-second increasing level time delay, 4-second decreasing level time delay, and 6-second LLCO time delay.
Warrick general purpose, 10,000 ohm, direct acting, 120v, retrofit level control with retrofit plate included.
Warrick threaded single probe fitting with a 1" NPT mounting that is rated to 125 psig at 353°F.
Warrick threaded single probe fitting with a 1" NPT mounting that is rated to 250 psig at 406°F.
Warrick threaded 3-probe fitting with a 2" NPT mounting that is rated to 250 psig at 406°F.
Warrick 3/8" threaded steam column probe with a 3/4" long Teflon sleeve.
Warrick one-piece extended 12" core fitting probe with a 5/8"-24 UNEF mounting that is rated to 250 psig at 406°F.
Warrick general purpose 12" stainless steel probe with a 1/4" mounting.
Warrick general purpose, direct acting, 8 pin DIN, socket style liquid level control with 10,000 ohm sensitivity. This level control has a 120 Vac supply and a SPDT (1 normally open/1 normally closed) relay. It is a plug-in module with no enclosure and a screw connector socket.
Warrick general purpose 120v, direct-acting low water cut-off liquid level control board with no enclosure in a retrofit standoff style. This control has a SPDT (1 normally open/1 normally closed) relay, built-in 3-second time delay, manual reset, remote-mount normally closed pushbutton, and spade terminals.
Warrick general purpose 24v, direct-acting low water cut-off liquid level control board with no enclosure in a 1/16" panel standoff style. This control has a SPDT (1 normally open/1 normally closed) relay, built-in 3-second time delay, and spade terminals.
Warrick general purpose 120v low water cut-off featuring a 1/16" standoff panel, power outage, and 10,000 ohm factory-set sensitivity.
Warrick general purpose 120v low water cut-off featuring a 1/16" standoff panel, power outage, 10,000 ohm factory-set sensitivity, and 6-second decreasing level time delay.
Warrick general purpose 120v low water cut-off featuring a retrofit standoff style, NEMA 1 enclosure, normally-closed pushbutton, and 10,000 ohm factory-set sensitivity.
Warrick general purpose 24v low water cut-off featuring a 1/16" standoff panel, 10,000 ohm factory-set sensitivity, and power outage.
Warrick general purpose 24v low water cut-off featuring a 1/16" standoff panel and 10,000 ohm factory-set sensitivity.
Warrick general purpose 24v low water cut-off featuring a 1/16" standoff panel, 10,000 ohm factory-set sensitivity, reset function, normally-closed pushbutton, power outage, and test feature.
Warrick general purpose 120v low water cut-off featuring a 10,000 ohm factory-set sensitivity, 1/8" standoff panel style, and power outage.
Warrick general purpose 120v low water cut-off featuring a 10,000 ohm factory-set sensitivity, retrofit standoff panel style, power outage, normally-closed pushbutton, and retrofit plate.
Warrick general purpose 120v low water cut-off featuring a 26,000 ohm factory-set sensitivity, 1/8" panel standoff panel style, and power outage.
Warrick general purpose 120v low water cut-off featuring a 26,000 ohm factory-set sensitivity and screw mount standoff panel style.
Warrick general purpose 120v low water cut-off featuring a 26,000 ohm factory-set sensitivity, retrofit standoff panel style, reset function, normally-closed pushbutton, and test feature.
Warrick 120v low water cut-off plug-in module featuring a 10,000 ohm factory-set sensitivity, 11 pin octal socket style, reset function, normally-closed pushbutton, test feature, and power outage.
Warrick 120v low water cut-off plug-in module featuring a 10,000 ohm factory-set sensitivity, 11 pin octal socket style, and power outage.
Warrick 120v low water cut-off plug-in module featuring a 10,000 ohm factory-set sensitivity, 11 pin octal socket style, normally-closed pushbutton, and power outage.
Warrick 120v low water cut-off plug-in module featuring a 26,000 ohm factory-set sensitivity and 11 pin octal socket style.
Warrick 120v low water cut-off plug-in module featuring a 26,000 ohm factory-set sensitivity, 11 pin octal socket style, and power outage.
Warrick 120v low water cut-off plug-in module featuring a 26,000 ohm factory-set sensitivity, DIN mount socket style, and power outage.
Warrick 120v low water cut-off liquid level controls plug-in module with no enclosure, manual reset (with power outage feature), remote mount normally closed push-button, test feature, and screw connector socket featuring a 10,000-ohm factory-set sensitivity and 11 pin octal socket style.
Warrick general purpose, top-mounting liquid level accessory with a cast iron body, epoxy coated die-cast aluminum terminal housing, four (4) electrode probe fittings, a 2-1/2" NPT tank connection, and a 1/2" NPT conduit connection.